This system is specifically designed for high accuracy or basis of payment applications requiring certification by government and regulatory agencies. It is extremely accurate to within 0.125% and is the most widely certified belt scale in the world. It has received its Certificate of Conformance in the United States as issued under the National Type Evaluation Program (NTEP) of the National Conference on Weights and Measures. Outside of the U.S., it is certified by OIML and EEC Class I standards. It represents the world standard of accuracy and performance for loadout, inventory monitoring and fee-holder type applications.
Accuracy | Capable of ±1/4% accuracy on factory approved applications Certified for use as basis of payment scale |
---|---|
Description | Series 10-14 Belt Scale System including carriage/weighbridge, electronics and speed sensor |
Load Cells | Four (4) environmentally protected “S” type cell, excitation 10 ±5% VDC, safe to 150% lof load call capacity |
Temperature Range | Load Cell -54° to +93°C (-65° to +200°F) Micro-Tech Electronics Operating Temperature -20° to +60°C (-4° to +140°F), Storage Temperature -30° to +70C (-22° to +158°F) |
Certifications/Compliance | NTEP Approved (National Type Evaluation Program) OIML / MID approvals pending |
Electronics | Micro-Tech 9301 Premium Scale Integrator used with Micro-Tech 9301-D Digitizer or Micro-Tech 9201 Premium Scale Integrator used with junction box Approvals cCSAus, CE approved SIL-2, Tick Mark, GOST, and ATEX pending approvals |
Digital Speed Sensor Type | 61-12C Belt Speed Sensor, digital, brushless, weather-tight, cast aluminum with epxoy finish |
Unit Size | – |
A safety pull cable is attached to the actuating arm of the switch and terminated at fixed mounts at either end of a conveyor. Force applied to the pull cable at any position causes the actuating arm to move into a tripped-locked position and activates an alarm from one DPDT or two SPDT micro-switches, alerting equipment circuits of the stop condition. This will stay locked until manually reset by the reset lever.
Actuating Force (ROS) | 5 lb. Adjustable actuator angle increment 22.5° |
---|---|
Description | Conveyor Protection Switches |
Enclosure Rating | SAS NEMA Type-4X: Yellow poly enamel painted aluminum SAS Nickel Plated NEMA Type-4X: Nickel plated aluminum |
Outputs | SAS NEMA Type-4X: 2 or 4 SPDT contacts rated for 6A @ 250 VAC SAS Nickel Plated NEMA Type-4X: 2 or 4 SPDT contacts rated for 6A @ 250 VAC |
Pull Force Rating (SPS) | 3.63 – 8.16kg (8 – 18 lb.) Pull cord lock angle: 15° |
Spacing (SPS) | SAS NEMA Type-4X: 45.7m (150 ft) spacing between pull cord switches SAS Nickel Plated NEMA Type-4X: 45.7m (150 ft) spacing between pull cord switches |
Temperature Range | Operating temperature: -40°C to 85°C (-40°F to 185°F) |
Unit Size | – |

This tramp metal detector minimizes lost production by providing an economical and reliable means to protect expensive crushers, conveyors and other process equipment from damage by tramp metal. It can detect all types of metallic scrap, including bucket teeth, manganese steel mantles, bore crowns, bar scrap chains, tools and more. Because the Thermo Scientific Ramsey Oretronic IV is insensitive to materials with high magnetic permeability and electrical conductivity, it can be used in applications where conventional metal detectors produce an unacceptable false alarm rate. It is designed especially for belt conveyors moving coal, iron pellets, minerals, aggregates and other bulk materials.
Belt Speed | 1.5 m/min to 550 m/min (5 ft/min to 1800 ft/min) |
---|---|
Communication Ports | Optional RS-485 serial communication |
Description | Oretronic IV Tramp Metal Detector, 4 Control |
Display Type | 77 mm x 58 mm viewable LCD graphic display for easy reading, continuous backlit for ease of viewing indoors and outdoors |
Enclosure Material | Reinforced fiberglass conforms to NEMA-4X, IP66 dust and water tight |
Enclosure Size | 432 mm (17 in) x 360 mm (14.2 in) x 184 mm (7.2 in) |
Input/Output | Input Power Requirments: 98-253 (fiberglass enclosure) or 115-230 VAC (steel enclosure) VAC, +10%, -15% 50/60 Hz Single phase, 0.9A (fiberglass enclosure) or 2.8A (steel enclosure)Output Relay Rating: User supplied 5A max, 250 VAC or 30 VDC NO and NC Contacts: Alarm Indicator, Alarm, Marker Output NC Contacts: Bypass, Power OK |
Operating Temperature | -40°C to +58°C (-40°F to +136°F) with Optional Heater: -50°C to +58°C (-58°F to +136°F) |
Overall Humidity | 10% up to 95%, non-condensing |
Storage Temperature | -30°C to +70°C (-22°F to +158°F) |
Certifications/Compliance | ISO-9001 Certified |
Electronics | Switch seletable 115/230 VAC, +10%, -15% 50/60 Hz Single phase, 30 VA, 0.25A |
Unit Size | – |